Firmware V1.0.0.18 for MOTUS®C14 & OMUS®C14

Download: Firmware V1.0.0.18 for MOTUS®C14 & OMUS®C14

Release Notes:
Ability to unlock feature upgrades via software

  • Subsequent activation of new functionalities on devices that have already been installed
  • Individual configuration of devices as required

Softstart functionality in three-phase operation (only MOTUS C14)

  • Phase control of all phases for optimized motor startup
  • Configuration options: 
    • Soft start active/inactive
    • Minimum voltage (50 – 95%)
    • Ramp-up time (0.1 – 20s)

Revision of the IO-Link stack 
Bug fixes and other stability improvements

Firmware V1.0.0.14 for MOTUS®C14 & OMUS®C14

Download: Firmware V1.0.0.14 for MOTUS®C14 & OMUS®C14

Release Notes:
Ability to unlock feature upgrades via software

  • Subsequent activation of new functionalities on devices that have already been installed
  • Individual configuration of devices as required

Softstart functionality in three-phase operation (only MOTUS C14)

  • Phase control of all phases for optimized motor startup
  • Configuration options: 
    • Soft start active/inactive
    • Minimum voltage (50 – 95%)
    • Ramp-up time (0.1 – 20s)

Revision of the IO-Link stack 
Bug fixes and other stability improvements

 

Firmware V0.6.0.6 MOTUS®C14 / OMUS®C14

Download: V0.6.0.6 for MOTUS®C14 & OMUS®C14
 

Software modifications / Bugfixes

  • Bugfix - Device restarts sporadically after multiple configurations via USB
  • Reading out the unique device ID


Sonstige Anmerkungen

  • Bugfix version to fix a sporadic problem with USB during configuration

 

Firmware V0.6.0.3 MOTUS®C14 / OMUS®C14

Download:
Firmware PV0.6.0.3 for MOTUS®C14 & OMUS®C14

Release notes : MOTUS®C14 / OMUS®C14 Firmware V0.6.0.3

Single-Phase Operation

  • Capability to set Single-Phase Operation mode
  • 3x 1~ Motor control (L – N)
  • Extended Load diagnostics to each phase (Short Circuit, Overload undercurrent, Phase Loss, Supply Loss, Undervoltage, Overvoltage)

Extension of Acyclic IO-Link Data

  • Capability to set all configuration values (3-Phase/1-Phase) via IO-Link
  • Extended Process data to support Single-Phase control

Initial support for OMUS®C14

  • Resistive Operation mode
  • Extended max. control frequency up to 20Hz for resistive load
  • Added Resistive TripClass

 

Wöhner GmbH & Co. KG