Previous firmware versions
Firmware V1.0.0.18 for MOTUS®C14 & OMUS®C14
Download: Firmware V1.0.0.18 for MOTUS®C14 & OMUS®C14
Release Notes:
Ability to unlock feature upgrades via software
- Subsequent activation of new functionalities on devices that have already been installed
- Individual configuration of devices as required
Softstart functionality in three-phase operation (only MOTUS C14)
- Phase control of all phases for optimized motor startup
- Configuration options:
- Soft start active/inactive
- Minimum voltage (50 – 95%)
- Ramp-up time (0.1 – 20s)
Revision of the IO-Link stack
Bug fixes and other stability improvements
Firmware V1.0.0.14 for MOTUS®C14 & OMUS®C14
Download: Firmware V1.0.0.14 for MOTUS®C14 & OMUS®C14
Release Notes:
Ability to unlock feature upgrades via software
- Subsequent activation of new functionalities on devices that have already been installed
- Individual configuration of devices as required
Softstart functionality in three-phase operation (only MOTUS C14)
- Phase control of all phases for optimized motor startup
- Configuration options:
- Soft start active/inactive
- Minimum voltage (50 – 95%)
- Ramp-up time (0.1 – 20s)
Revision of the IO-Link stack
Bug fixes and other stability improvements
Firmware V0.6.0.6 MOTUS®C14 / OMUS®C14
Download: V0.6.0.6 for MOTUS®C14 & OMUS®C14
Software modifications / Bugfixes
- Bugfix - Device restarts sporadically after multiple configurations via USB
- Reading out the unique device ID
Sonstige Anmerkungen
- Bugfix version to fix a sporadic problem with USB during configuration
Firmware V0.6.0.3 MOTUS®C14 / OMUS®C14
Download:
Firmware PV0.6.0.3 for MOTUS®C14 & OMUS®C14
Release notes : MOTUS®C14 / OMUS®C14 Firmware V0.6.0.3
Single-Phase Operation
- Capability to set Single-Phase Operation mode
- 3x 1~ Motor control (L – N)
- Extended Load diagnostics to each phase (Short Circuit, Overload undercurrent, Phase Loss, Supply Loss, Undervoltage, Overvoltage)
Extension of Acyclic IO-Link Data
- Capability to set all configuration values (3-Phase/1-Phase) via IO-Link
- Extended Process data to support Single-Phase control
Initial support for OMUS®C14
- Resistive Operation mode
- Extended max. control frequency up to 20Hz for resistive load
- Added Resistive TripClass
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Germany
Contact
+49 9563 751-0
info@woehner.de
Newsletter
Newsletter subscription
Order hotline
+49 9563 751-161
order@woehner.de
Technology hotline
+49 9563 751-260
support@woehner.com